Products Description
The 500KVA Yuchai Engine Diesel Genset provides approximately 400KW rated electrical output and is designed for industrial facilities, commercial buildings, construction projects, infrastructure sites and other applications requiring reliable high-capacity power.
Powered by a Yuchai diesel engine and matched with a brushless AC alternator, the generator set provides stable power output under changing load conditions. Depending on the project requirements, the genset can be supplied as an open type, silent type or customized power system, with options including ATS, remote monitoring and synchronization.

Product Highlights
500KVA / 400KW Power Output
Designed for medium-to-large electrical loads in industrial, commercial and engineering applications.
Yuchai Diesel Engine
Powered by a Yuchai industrial diesel engine with strong load response and reliable operating performance.
Prime & Standby Power
Suitable for both continuous power applications and emergency backup power systems.
Flexible Electrical Configuration
Available in 50Hz or 60Hz with different voltage configurations according to destination market requirements.
Multiple Generator Configurations
Open type, silent type, ATS system, remote monitoring and parallel operation can be configured according to the project.
Factory Tested Before Shipment
Generator output, controller functions, protection systems and operating performance are inspected before delivery.
Technical Specifications
| Item | Specification |
|---|---|
| Product Name | 500KVA Yuchai Engine Diesel Genset |
| Rated Power | Approx. 400KW / 500KVA |
| Standby Power | Up to approx. 440KW / 550KVA* |
| Engine Brand | Yuchai |
| Engine Type | 4-Stroke Diesel Engine |
| Cooling System | Water Cooled |
| Frequency | 50Hz / 60Hz |
| Voltage | 400V / 230V or Customized |
| Phase | Three Phase |
| Power Factor | 0.8 |
| Starting System | Electric Start |
| Alternator | Brushless AC Alternator |
| Voltage Regulation | AVR |
| Controller | Digital Generator Controller |
| Operating Mode | Prime / Standby |
| Generator Type | Open / Silent / Customized |
| ATS | Optional |
| Synchronization | Optional |
| Remote Monitoring | Optional |
Is 500KVA Enough for Your Project?
Selecting a diesel generator should not be based only on the total connected electrical load.
For large industrial and commercial projects, several additional factors should be considered:
Total Load → Motor Starting Current → Power Factor → Load Sequence → Future Capacity → Generator Selection
A 500KVA generator is normally equivalent to approximately 400KW at a 0.8 power factor, but this does not necessarily mean that every project with less than 400KW of connected equipment can use the same generator configuration.
Large motors, pumps, compressors and similar equipment may require several times their normal operating current during startup.
Generator sizing should therefore consider:
- Total operating load
- Maximum simultaneous load
- Motor starting current
- Power factor
- Load starting sequence
- Nonlinear electrical loads
- Required backup capacity
- Future expansion
For projects involving large motors or complicated electrical systems, our team can assist with generator selection according to the actual load information.
Prime Power or Standby Power
The 500KVA Yuchai diesel generator can be configured for different operating modes.
Standby Power
Used as an emergency power source when the utility grid is normally available.
Typical applications include:
- Commercial buildings
- Hospitals
- Factories
- Data and communication facilities
- Office buildings
- Infrastructure projects
When utility power fails, an optional ATS can automatically start the generator and transfer the electrical load.
Prime Power
Used where the generator serves as the main power source or operates for extended periods.
Typical applications include:
- Remote construction projects
- Mining operations
- Temporary industrial facilities
- Remote production sites
- Areas with unstable utility power
The appropriate generator rating should be selected according to the expected operating hours and average load.
Installation Considerations
Correct generator installation is important for safe and reliable operation
The generator room should provide sufficient fresh air for engine combustion and cooling.
Hot air generated by the radiator should be discharged efficiently to prevent excessive room temperature.
The exhaust system should be properly sized and routed to safely discharge exhaust gases outside the building.
Fuel tank capacity should be selected according to the required operating time and local installation requirements.
A stable and level installation foundation helps minimize vibration and keeps the generator correctly aligned.
Adequate clearance should be maintained around the generator for routine inspection, filter replacement, repair and servicing.
Custom 500KVA Generator Solutions
Different projects may require different generator configurations.
DBD Power can provide customization options including:
- 50Hz / 60Hz
- Customized voltage
- Open type
- Silent canopy
- Automatic Transfer Switch
- Large-capacity fuel tank
- Remote monitoring
- Synchronization system
- Parallel operation
- Customized controller
- Customized enclosure
- OEM logo and color
For distributors, engineering contractors and generator rental companies, standardized configurations can also be developed for repeated orders.

Get a 500KVA Yuchai Generator for Your Project
Looking for a 500KVA Yuchai Engine Diesel Genset for industrial, commercial or project power supply?
Send us your required power, voltage, frequency, application, configuration and quantity. Our team can help you select a suitable diesel generator solution according to your project requirements.
Hot Tags: 500kva yuchai engine diesel genset, China 500kva yuchai engine diesel genset manufacturers, suppliers, factory








